Timber Frame Application Walls
Daubs of BGC Stud Adhesive, 25mm diameter x 15mm high are positioned in the pattern spaced at a maximum of 300mm and a minimum of 200mm.
BGC Stud Adhesive must not be used at wall-to-wall and wall-to-ceiling junctions, around openings, butt joints or fastener points. BGC Plasterboard is placed horizontally along each wall.
Sheets to be packed 6-10mm from floor and fastened along the top recessed edge at each stud or furring channel.
The sheets are then pressed firmly against the studs and temporary fastened midway across the sheet at every second stud or furring channel. Next, fasten the other recessed edge at each stud, or furring channel.
Fasteners must not coincide with BGC Stud Adhesive daubs, and fasteners should be kept to a minimum distance of 200mm from adhesive daubs. Fasteners around openings should be placed at a maximum spacing of 300mm centres. Allow at least 24 hours for the adhesive to set.